AIR RELIEF DETAILS (Drawing Numbers & Description)
STD-A01 2" AIR RELIEF VALVE FOR STEEL WATER MAINS (DATED 5-15-2007)
STD-A02 2" AIR RELIEF VALVE FOR CONCRETE MAINS
(DATED 5-15-2007)
STD-A03 2" AIR RELIEF VALVE FOR DUCTILE IRON MAINS
(DATED 5-15-2007)
STD-A04 2" AIR RELIEF VALVE FOR DUCTILE IRON MAINS ON BRIDGES
(DATED 9-24-10)

Return to top of the page

8" CHECK VALVE IN VAULT
Download PDF Now
PLAN VIEW (click here for PDF version)
Download PDF Now
ELEVATION VIEW (Click here for PDF version)

Return to top of the page

CONNECTION DETAILS (Drawing Numbers & Description)
STD-C01 WATER SERVICE CONNECTION EXTENSION OR REPLACEMENT FOR 1" & SMALLER; (DATED 5-11-98)
STD-C02 WATER SERVICE CONNECTION EXTENSION FOR 1-1/2" & 2" (DATED 10-1-97)
STD-C03 WATER SERVICE CONNECTION REPLACEMENT FOR 1-1/2" & 2" (DATED 10-1-97)
STD-C04 NEW 1" SERVICE CONNECTION DETAIL IN PUBLIC RIGHT OF WAY; (DATED 10-1-97)
STD-C05 TWO-PLEX SETTING FOR REMOTE REGISTER METER AT BUILDING –PLAN; (DATED 10-1-97)
STD-C06 TWO-PLEX SETTING FOR REMOTE REGISTER METER AT BUILDING –PROFILE; (DATED 10-1-97)
STD-C07 THREE-PLEX SETTING FOR REMOTE REGISTER METER AT BUILDING; (DATED 10-1-97)
STD-C08 FOUR-PLEX SETTING FOR REMOTE REGISTER METER AT BUILDING; (DATED 10-1-97)
STD-C09 EXTEND 3" & LARGER CONNECTION; (DATED 9-16-98)
STD-C10

NEW WATER SERVICE CONNECTION FOR 1-1/2" & 2"
(DATED 6-21-2000)

STD-C11 New Water Service Connection for 3" and Larger Connection (9-23-2008)
1" GENERAL SUPPLY
REQ'D
SIZE
DESCRIPTION
1
1"
COPPER TO IRON FLARE CORPORATION STOP
1
1"
COPPER TO COPPER OR COPPER TO IRON FLARE CURB STOP
1
CURB STOP BOX COMPLETE (BOTTOM, TOP AND COVER)
X#FT.
1"
COPPER TUBING
1-1/2" GENERAL SUPPLY
REQ'D
SIZE
DESCRIPTION
1
SOM x 1-1/2"
STRAP SADDLE
2
1-1/2"
COPPER TO IRON MALE COMPRESSED UNION
2
1-1/2"
IRON TO IRON BALL TYPE VALVE
1
1-1/2" x 6"
BRASS NIPPLE
2
1-1/2"
#2 VALVE BOX TOP
2
1-1/2"
#2 VALVE BOX BOTTOM
2
1-1/2"
#2 VALVE BOX COVER
2
1-1/2"
STATIONARY EXTENSION ROD (IF NEEDED)
X#FT.
1-1/2"
COPPER TUBING
2" GENERAL SUPPLY OR 2" FIRE LINE
REQ'D
SIZE
DESCRIPTION
1
SOM x 2"
STRAP SADDLE
2
2"
COPPER TO IRON MALE COMPRESSED UNION
2
2"
IRON TO IRON BALL TYPE VALVE
1
2" x 6"
BRASS NIPPLE
2
2"
#2 VALVE BOX TOP
2
2"
#2 VALVE BOX BOTTOM
2
2"
#2 VALVE BOX COVER
2
2"
STATIONARY EXTENSION ROD (IF NEEDED)
X#FT.
2"
COPPER TUBING
 
ON CONCRETE PIPE
THE SAME MATERIALS AS SPECIFIED ABOVE ARE USED FOR CONNECTION INSTALLATIONS ON A CONCRETE PIPE, PLUS 2 BAND TAPPING SADDLE FOR CONCRETE PIPE.
 

ABOUT METERING 1" WATER CONNECTIONS
IN MOST CASES 1" WATER CONNECTIONS SERVE AS DOMESTIC SERVICE TO RESIDENTIAL PROPERTIES. STANDARDLY, THE METER FOR THESE SIZE CONNECTIONS ARE INSTALLED INDOORS WITH A READOMATIC REGISTER ATTACHED TO THE OUTSIDE OF THE BUILDING. (INSTALLATION DIAGRAM “IBMS” SHOWS THE STANDARD APPROVED INSIDE METER SETTING.) WHERE METER VAULTS ARE REQUIRED, 1" METERS ARE INSTALLED ON RISERS

 

** SPECIAL NOTE **
CURB STOP BOXES ARE AN APPROVED CAST IRON.

 

NOTE: IF 1-1/2" OR 2" CONNECTION IS TO BE LONGER THAN TWENTY FEET, ONE ADDITIONAL STREAMLINE COUPLING (COPPER TO COPPER) IS TO BE ADDED FOR EACH ADDITIONAL TWENTY FOOT LENGTH OR EACH PORTION (20') OVER THE INITIAL TWENTY FEET, (A COMPRESSION 3 PART UNION, COPPER TO COPPER, CAN BE USED). THESE WILL BE 1-1/2" OR 2" DEPENDING ON WHAT SIZE CONNECTION IS BEING INSTALLED, UNLESS 1-1/2" OR 2" COPPER IS ROLLED SOFT COPPER.

 

*SOM MEANS SIZE OF MAIN

SEE DRAWING STD-V01 & V02

Return to top of the page

GENERAL DETAILS (Drawing Numbers & Description)
STD-001 WATER MAIN TRENCH DETAIL (DATED 2-2-2012)
STD-002 ALTERNATE PRESSURE TESTING DETAIL (DATED 10-1-97)
STD-003 TYPICAL FLUSHING ASSEMBLY (DATED 5-15-2007)
STD-004 PLUGGING ABANDONED WATER MAIN ENDS
(DATED 10-1-97)
STD-005 CUT-IN-VALVE DETAIL (DATED 10-1-97)
STD-006 TYPICAL THRUST BLOCK DETAIL FOR HORIZONTAL DEFLECTION FOR PIPE UP TO 16" DIAMETER
(DATED 1-15-98)
STD-007 SLEEVE INSTALLATION DETAIL (DATED 10-1-97)
STD-008 SPOOL PIECE INSTALLATION DETAIL (DATED 10-1-97)
STD-009 TYPICAL FROSTPROOFING DETAIL (DATED 10-1-97)
STD-010

TYPICAL PAVEMENT SECTION (DATED 2-6-98)

STD-011a

CONSTRUCTION NOTES PAGE 1 (NOTES 1 – 11) DATED 5-20-2008

STD-011b CONSTRUCTION NOTES PAGE 2 (NOTES 12 – 17) DATED 5-20-2008
STD-012 STRAIGHT CUL-DE-SAC SCHEMATIC (DATED 6-14-2001)
STD-013 STANDARD CUL-DE-SAC HYDRANT/LOOP SCHEMATIC
(DATED 6-14-2001)
STD-014 ALTERNATE CUL-DE-SAC HYDRANT/LOOP SCHEMATIC
(DATED 6-14-2001)
STD-015 CASING DETAIL No. 1 END OF CASING AND HARDWOOD BLOCK DETAIL-OBSOLETE (DATED 10-1-97)
STD-016 CASING DETAIL No. 2 END OF CASING AND CASING CHOCK DETAIL (DATED 1-21-2010)
STD-017 CLEARANCE FOR UTILITES - PLAN VIEW
(DATED 12-4-97)
STD-018 CLEARANCE FOR UTILITES - PROFILE VIEW
(DATED 12-4-97)
STD-019 CROSSING LARGE DITCHES OR SMALL STREAMS PROFILE- OPEN CUT METHOD - (DATED 9-16-98)
STD-020

CROSSING LARGE DITCHES OR SMALL STREAMS SECTION A-A OPEN CUT METHOD (DATED 9-16-98)

STD-021 SPLIT CASING DETAIL - (DATED 9-16-1999)
STD-022 GUARDRAIL DETAILS AT HYDRANT - (DATED 10-15-1999)
STD-023 SERVICE CONNECTION BACKFILL DETAIL
(DATED 10-7-2008)

Return to top of the page

HYDRANT DETAILS (Drawing Numbers & Description)
STD-H01 DISTURBING EXISTING LEADED HYDRANTS AND LEADED FITTINGS (DATED 5-4-2006)
STD-H02 EXTEND, SHORTEN AND ADJUST EXISTING 6" HYDRANT TO GRADE, STRAIGHT TYPE (DATED 5-4-2006)
STD-H03 EXTEND, SHORTEN AND ADJUST EXISTING 6" HYDRANT TO GRADE, OFFSET TYPE 1 (DATED 5-4-2006)
STD-H04 EXTEND, SHORTEN AND ADJUST EXISTING 6" HYDRANT TO GRADE, OFFSET TYPE 2 (DATED 5-4-2006)
STD-H05 EXTEND, SHORTEN AND ADJUST HYDRANT TO GRADE, OFFSET TYPE 3 (DATED 5-4-2006)
STD-H06 REPLACING EXISTING HYDRANT WITH NEW 6” HYDRANT, STRAIGHT TYPE (DATED 5-4-2006)
STD-H07 EXTEND, SHORTEN AND ADJUST EXISTING 6" HYDRANT TO GRADE, OFFSET TYPE (DATED 5-4-2006)
STD-H08 CUT-IN TEE FOR NEW HYDRANT INSTALLATION ON EXISTING WATER MAIN (DATED 10-1-97)
STD-H09 TYPICAL NEW HYDRANT INSTALLATION DETAIL A
(DATED 3-4-2002)
STD-H10

TYPICAL NEW HYDRANT INSTALLATION DETAIL B
(DATED 10-1-97)

STD-H11 TYPICAL NEW HYDRANT INSTALLATION DETAIL C
(DATED 3-4-2002)
STD-H12 ADJUSTING 6" HYDRANT ELEVATION (DATED 2-23-2005)
STD-H13 6" HYDRANT ELEVATION
(DATED 2-23-2005)
STD-H14 TEMPORARY WATER MAIN & HYDRANT CONNECTION ASSEMBLY-A (DATED 10-1-97)
STD-H15 TEMPORARY WATER MAIN & HYDRANT CONNECTION ASSEMBLY-B HYDRANT END - OBSOLETE
(DATED 2-11-03)
STD-H16 TEMPORARY WATER MAIN & HYDRANT CONNECTION ASSEMBLY-C OUTLET END (DATED 10-1-97)

Return to top of the page

LOWERING DETAILS (Drawing Numbers & Description)
STD-L01 PIPE LOWERING (DATED 11-24-2003)
STD-L02

DETAIL FOR TYPICAL WATER MAIN LOWERING ON OBSTRUCTIONS LESS THAN 24" IN DIAMETER OR WIDTH FOR EXISTING CONSTRUCTION (DATED 3-4-2002)

STD-L03

DETAIL FOR TYPICAL WATER MAIN LOWERING ON OBSTRUCTIONS 24" & LARGER IN DIAMETER OR WIDTH FOR EXISTING CONSTRUCTION (DATED 3-4-2002)

STD-L04 DETAIL FOR TYPICAL WATER MAIN LOWERING ON OBSTRUCTIONS LESS THAN 24" IN DIAMETER OR WIDTH FOR NEW CONSTRUCTION (DATED 10-1-97)
STD-L05

DETAIL FOR TYPICAL WATER MAIN LOWERING ON OBSTRUCTIONS 24"& LARGER IN DIAMETER OR WIDTH FOR NEW CONSTRUCTION (DATED 10-1-97)

STD-L06 DETAIL FOR WATER MAIN LOWERING USING MECHANICAL JOINT OFFSETS UNDER OBSTRUCTIONS LESS THAN 24" IN DIAMETER OR WIDTH FOR NEW CONSTRUCTION
(DATED 12-3-2009)
STD-L07 DETAIL FOR WATER MAIN LOWERING USING MECHANICAL JOINT OFFSETS UNDER OBSTRUCTIONS 24" & LARGER IN DIAMETER OR WIDTH FOR NEW CONSTRUCTION
(DATED12-3-2009)
STD-L08 DETAIL FOR WATER MAIN LOWERING USING MECHANICAL JOINT OFFSETS UNDER OBSTRUCTIONS LESS THAN 24" IN DIAMETER OR WIDTH FOR EXISTING CONSTRUCTION
(DATED 12-3-2009)
STD-L09 DETAIL FOR WATER MAIN LOWERING USING MECHANICAL JOINT OFFSETS UNDER OBSTRUCTIONS 24" & LARGER IN DIAMETER OR WIDTH FOR EXISTING CONSTRUCTION
(DATED 12-3-2009)

Return to top of the page

METER SETTING DETAILS (Drawing Numbers & Description)
STD-M01

STANDARD 1-1/2" METER SETTING WITH 1-1/2" METER FOR VAULTS (DATED 10-1-97) AND BILL OF MATERIAL (DATED 12-10-98)
(Materials Required for Installation - click here)

STD-M02

STANDARD 2" METER SETTING WITH 2" METER FOR VAULTS (DATED 10-1-97) AND BILL OF MATERIAL
(DATED 12-10-98)
(Materials Required for Installation - click here)

STD-M03

APPROVED 2" METER SETTING FOR 2" METER AND BACKFLOW ASSEMBLY FOR VAULTS LAWN IRRIGATION ONLY (DATED 10-1-97) AND BILL OF MATERIAL
(DATED 12-10-98)
(Materials Required for Installation - click here)

STD-M04

STANDARD 3" METER SETTING WITH 2" METER FOR VAULTS -PLAN- (DATED 10-1-97) AND BILL OF MATERIAL (DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M05

STANDARD 3" METER SETTING WITH 2" METER FOR VAULTS -ELEVATION- (DATED 10-1-97) AND BILL OF MATERIAL (DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M06

STANDARD 3" METER SETTING WITH 3" METER FOR VAULTS -PLAN- (DATED 10-1-97) AND BILL OF MATERIAL (DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M07

STANDARD 3" METER SETTING WITH 3" METER FOR VAULTS -ELEVATION- (DATED 10-1-97) AND BILL OF MATERIAL (DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M08

STANDARD 4" METER SETTING WITH 4" METER FOR VAULTS (DATED 10-1-97) AND BILL OF MATERIAL
(DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M09

STANDARD 4" METER SETTING WITH 3" METER FOR VAULTS (DATED 5-18-98) AND BILL OF MATERIAL
(DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M10

STANDARD 6" METER SETTING WITH 6" METER FOR VAULTS (DATED 4-26-2005) AND BILL OF MATERIAL
(DATED 4-26-2005)
(Materials Required for Installation - click here)

STD-M11

STANDARD 6" METER SETTING WITH 4" METER FOR VAULTS (DATED 5-18-98) AND BILL OF MATERIAL
(DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M12

STANDARD 8" METER SETTING WITH 8" METER FOR VAULTS (DATED 10-1-97) AND BILL OF MATERIAL
(DATED 11-19-98)
(Materials Required for Installation - click here)

STD-M13

STANDARD 8" METER SETTING WITH 6" METER FOR VAULTS (DATED 4-26-2005) AND BILL OF MATERIAL
(DATED 4-26-2005)
(Materials Required for Installation - click here)

STD-M14

STANDARD 12" METER SETTING WITH 12" METER FOR VAULTS (DATED 10-1-97) AND BILL OF MATERIAL
(DATED 3-06-09)
(Materials Required for Installation - click here)

STD-M15

TYPICAL 3", 4", 6", AND 8" METER SETTINGS WITH 1", 1-1/2" OR 2" LAWN SPRINKLER CONNECTION
(DATED 1-4-2010)

STD-M16

TYPICAL 1-1/2" & 2" METER SETTINGS WITH 1" & 1-1/2" LAWN SPRINKLER CONNECTION (DATED 10-1-97)

STD-M17 APPROVED INSIDE BUILDING METER SETTINGS FOR 5/8", 1" METERS. (DATED 11-3-2011)
STD-M18

APPROVED INSIDE BUILDING METER SETTINGS FOR 5/8", 1" METERS FOR SEWER EXEMPTION.
(DATED 8-18-2011)

STD-M19

APPROVED INSIDE BUILDING METER SETTING FOR 1-1/2" METER AND CHECKVALVE. OBSOLETE
(DATED 11-26-97
)

STD-M20

APPROVED INSIDE BUILDING METER SETTING FOR 1-1/2" METER AND BACKFLOW ASSEMBLY.
(DATED 10-1-97
)

STD-M21

APPROVED INSIDE BUILDING METER SETTING FOR 2" METER AND CHECKVALVE. OBSOLETE (DATED 11-26-97)

STD-M22

APPROVED INSIDE BUILDING METER SETTING FOR 2" METER AND BACKFLOW ASSEMBLY. (DATED 10-1-97)

STD-M23

APPROVED 1-1/2" METER SETTING FOR 1-1/2" METER AND BACKFLOW ASSEMBLY FOR VAULTS LAWN IRRIGATION ONLY (DATED 10-23-97)

STD-M24

APPROVED 1" METER SETTING FOR 1" METER AND BACKFLOW ASSEMBLY FOR VAULTS LAWN IRRIGATION ONLY (DATED 1-4-2010)

STD-M25 STANDARD 1-1/2" METER SETTING WITH 1-1/2" METER IN VAULT FOR 2" CONNECTION (DATED 1-12-1999) AND BILL OF MATERIAL (DATED 1-12-99)
(Materials Required for Installation - click here)
STD-M26

STANDARD 1" METER SETTING WITH 1" REGULATOR FOR 2" CONNECTION IN VAULT (DATED 1-12-1999)

STD-M27

STANDARD 1" METER SETTING WITH 1" REGULATOR FOR 1-1/2" CONNECTION IN VAULT (DATED 1-12-1999)

STD-M28

STANDARD 1" METER SETTING FOR 2" CONNECTION IN VAULT (DATED 1-12-1999)

STD-M29

STANDARD 1" METER SETTING FOR 1-1/2" CONNECTION IN VAULT (DATED 1-12-1999)

STD-M30

STANDARD 1" SERVICE CONNECTION WITH CLEVELAND STANDARD METER PIT WITH REGULATOR DETAIL IN PUBLIC RIGHT OF WAY (DATED 10-12-2007)

STD-M31

STANDARD 1" SERVICE CONNECTION WITH CLEVELAND STANDARD METER PIT DETAIL IN PUBLIC RIGHT OF WAY (DATED 10-12-2007)

STD-M32

STANDARD 1" SERVICE CONNECTION WITH CLEVELAND STANDARD METER PIT FOR IRRIGATION IN PUBLIC RIGHT OF WAY- OBSOLETE (DATED 5-20-1999)

STD-M33

3" IRRIGATION METER SETTING WITH 3" METER DATED 11-17-1999 AND BILL OF MATERIAL (DATED 1-4-2010)
(Materials Required for Installation - click here)

STD-M34

4" IRRIGATION METER SETTING WITH 4" METER DATED 3-13-2000 AND BILL OF MATERIAL (DATED 4-19-2000)
(Materials Required for Installation - click here)

STD-M35

6" IRRIGATION METER SETTING WITH 6" METER DATED 4-19-2000 AND BILL OF MATERIAL (DATED 4-19-2000)
(Materials Required for Installation - click here)

STD-M36 LARGE METER SETTINGS INSIDE BUILDINGS
(DATED 9-15-2004)
STD-M37

FM APPROVED 8" COMPOUND METER ASSEMBLY FOR VAULT DATED 5-25-2001 WITH BILL OF MATERIAL (DATED 5-25-2001)
(Materials Required for Installation - click here)

STD-M38

FM APPROVED 8" COMPOUND METER ASSEMBLY FOR VAULT SENSUS METER (DATED 6-25-2004) WITH BILL OF MATERIAL (DATED 11-29-2001)
(Materials Required for Installation - click here)

STD-M39

FM APPROVED 12" COMPOUND METER ASSEMBLY FOR VAULT DATED 6-25-2004 WITH BILL OF MATERIAL (DATED 6-25-2004)
(Materials Required for Installation - click here)

Return to top of the page

8" REGULATORS
DETAIL No.

8" REGULATOR (Drawing Numbers & Description)

8reg

8" REGULATOR (DATED 10-1-97) AND BI

8reg_p

8" REGULATOR -PLAN- (DATED 10-1-97)

8reg_e

8" REGULATOR - ELEVATION- (DATED 10-1-97)

8reg_aa

8" REGULATOR SECTION A-A (DATED 10-1-97)

8" REGULATOR (Bill of Materials download)
ITEM
REQ'D
SIZE
DESCRIPTION
1
1
8"
CLAYTON REGULATOR OR OCV REGULATOR OR EQUAL, FLANGED
2
1
8"
ROSS STRAINER, FLANGED
3
1
2"

CLAYTON REGULATOR OR OCV REGULATOR OR EQUAL, SCREWED OR FLANGED

4
1
2"
ROSS STRAINER, FLANGED
5
2
8"
O.S. & Y. GATE VALVE, FLANGED
6
1
8"
GATE VALVE, FLANGED OR RETAINED MECHANICAL JOINT WITH HAND WHEEL
7
2
2"

GATE VALVE, RETAINED MECHANICAL JOINT

8
2
2"

O.S. & Y. BRASS GATE VALVE, SCREWED

9
2
8"x8"x8"
TEE, RETAINED MECHANICAL JOINT
10
2
8"
90 DEGREE COMPACT ELBOW, RETAINED MECHANICAL JOINT x PLAIN END
11
2
8"x8"x4"
TEE, FLANGED
12
2
2"
90 DEGREE BRASS ELBOW, SCREWED
13
2
2"
UNIONS BRASS, SCREWED
14
2
2"x9"
REDUCING FLANGE, SCREWED
15
2
1/4"x4"
BRASS NIPPLE, SCREWED
16
2
1/4"
BALL VALVE BRASS, SCREWED
17
1
2"x2"x2"
BRASS TEE, SCREWED
18
1
2"x6"
BRASS NIPPLE, SCREWED
19
1
2"
BRASS GATE VALVE, SCREWED
20
1
2"
BRASS PLUG, SCREWED
21
2
2"
COMPANION FLANGE

NOTE: (4) 2” COMPANION FLANGES REQ’D IF FLANGED 2” REGULATOR IS USED

NOTE: PIPE LENGTHS ARE APPROXIMATE. CUT TO SUIT

ITEM
REQ'D
SIZE
DESCRIPTION
22
14-1/2" LONG
8"
CLASS 52 DUCTILE IRON PIPE PLAIN END x PLAIN END
23
14-1/2" LONG
8"
CLASS 52 DUCTILE IRON PIPE PLAIN END x PLAIN END
24
9" LONG
8"

CLASS 52 DUCTILE IRON PIPE FLANGED SPACER

25
103-3/4" LONG
8"
CLASS 52 DUCTILE IRON PIPE
FLANGED x PLAIN END
26
103-3/4" LONG
8"

CLASS 52 DUCTILE IRON PIPE FLANGED x PLAIN END

27
153-1/4" LONG or 1 PIPE LENGTH
8"
CLASS 52 DUCTILE IRON PIPE 1 PIPE LENGTH FLANGED x PLAIN END OR PLAIN END x PLAIN END TO MATCH ITEM 6
28
153-1/4" LONG or 1 PIPE LENGTH
8"
CLASS 52 DUCTILE IRON PIPE 1 PIPE LENGTH FLANGED x PLAIN END OR PLAIN END x PLAIN END TO MATCH ITEM 6
29
(4)2-5/16" LONG
2"
BRASS CLOSE NIPPLE
30
6" LONG
2"

BRASS PIPE

31
54-3/4" LONG
2"

BRASS PIP

32
12" LONG
2"

BRASS PIP

33
6" LONG
2"

BRASS PIP

34
6" LONG
2"

BRASS PIP

35
12" LONG
2"

BRASS PIPE

ITEM
REQ'D
SIZE
DESCRIPTION
36
80
3/4"x3-3/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
37
80
3/4"
HEX NUTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
38
10
8"

RING GASKETS

39
16
5/8"x3-1/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
40
2
4"
RING GASKETS
41
8
5/8"x2-3/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
42
2
2"
RING GASKETS
NOTE: (4) 2” RING GASKETS REQ’D IF FLANGED 2” REGULATOR IS USED
43
24
5/8"
HEX NUTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
44
12
8"

RETAINED MECHANICAL JOINTS WITH ACCESSORIES

14
8"

RETAINED MECHANICAL JOINTS WITH ACCESSORIES IF OPTIONAL SOLID SLEEVE USED

45
2
#2

VALVEBOXES SET TO GRADE FOR ITEM #7 (NOT SHOWN ON DRAWING FOR CLARITY)

46
1
8"

**OPTIONAL** RETAINED MECHAICAL JOINT SOLID SLEEVE (SHORT PATTERN)

 

Regulator Specifications

The regulator valve shall be a pressure reducing/pressure sustaining surge control valve of the globe type manufactured by Cla-Val Company (Series 94, CWD Reg.) or OVC Control Valves (Model No: 127-25).

The strainers shall be of the type manufactured by Ross Valve (Model No: 10B/10C).

The pressure reducing valve body and strainer body shall be either cast iron or ductile iron having a working pressure of minimum 250 psi.

All components of the pressure reducing valve assembly shall also have a minimum 250 psi working pressure rating.

The flanges of the pressure reducing valve, strainer, valves and connecting pieces shall have a working pressure of 250 psi with dimensions and drilling of all end flanges conforming to the American 125 lb. Cast Iron Flange Standard. Flanges shall be plain face with a smooth finish.

(SEE DRAWING No. 8REG)

6-11-1998

DETAIL No.

12" REGULATOR (Drawing Numbers & Description)

12reg

12" REGULATOR (DATED 10-1-97) AND BI
(Materials Required for Installation - click here)

12reg_p

12" REGULATOR -PLAN- (DATED 10-1-97)

12reg_e

12" REGULATOR - ELEVATION- (DATED 10-1-97)

12reg_aa

12" REGULATOR SECTION A-A (DATED 10-1-97)

12" REGULATOR
ITEM
REQ'D
SIZE
DESCRIPTION
1
1
12"
CLAYTON REGULATOR OR OCV REGULATOR OR EQUAL, FLANGED
2
1
12"
ROSS STRAINER, FLANGED
3
1
2"

CLAYTON REGULATOR OR OCV REGULATOR OR EQUAL, SCREWED OR FLANGED

4
1
2"
ROSS STRAINER, FLANGED
5
2
12"
O.S. & Y. GATE VALVE, FLANGED
6
1
12"
GATE VALVE, FLANGED OR RETAINED MECHANICAL JOINT WITH HAND WHEEL
7
2
12"

GATE VALVE, RETAINED MECHANICAL JOINT

8
2
2"

O.S. & Y. BRASS GATE VALVE, SCREWED

9
2
12"x12"x12"
TEE, RETAINED MECHANICAL JOINT
10
2
12"
90 DEGREE COMPACT ELBOW, RETAINED MECHANICAL JOINT x PLAIN END
11
2
12"x12"x4"
TEE, FLANGED
12
2
2"
90 DEGREE BRASS ELBOW, SCREWED
13
2
2"
UNIONS BRASS, SCREWED
14
2
2"x9"
REDUCING FLANGE, SCREWED
15
2
1/4"x4"
BRASS NIPPLE, SCREWED
16
2
1/4"
BALL VALVE BRASS, SCREWED
17
1
2"x2"x2"
BRASS TEE, SCREWED
18
1
2"x6"
BRASS NIPPLE, SCREWED
19
1
2"
BRASS GATE VALVE, SCREWED
20
1
2"
BRASS PLUG, SCREWED
21
2
2"
COMPANION FLANGE

NOTE: (4) 2” COMPANION FLANGES REQ’D IF FLANGED 2” REGULATOR IS USED

NOTE: PIPE LENGTHS ARE APPROXIMATE. CUT TO SUIT

ITEM
REQ'D
SIZE
DESCRIPTION
22
14-1/2" LONG
12"
CLASS 52 DUCTILE IRON PIPE PLAIN END x PLAIN END
23
14-1/2" LONG
12"
CLASS 52 DUCTILE IRON PIPE PLAIN END x PLAIN END
24
9" LONG
12"

CLASS 52 DUCTILE IRON PIPE FLANGED SPACER

25
103-3/4" LONG
12"
CLASS 52 DUCTILE IRON PIPE
FLANGED x PLAIN END
26
103-3/4" LONG
12"

CLASS 52 DUCTILE IRON PIPE FLANGED x PLAIN END

27
153-1/4" LONG or 1 PIPE LENGTH
12"
CLASS 52 DUCTILE IRON PIPE 1 PIPE LENGTH FLANGED x PLAIN END OR PLAIN END x PLAIN END TO MATCH ITEM 6
28
153-1/4" LONG or 1 PIPE LENGTH
12"
CLASS 52 DUCTILE IRON PIPE 1 PIPE LENGTH FLANGED x PLAIN END OR PLAIN END x PLAIN END TO MATCH ITEM 6
29
(4)2-5/16" LONG
2"
BRASS CLOSE NIPPLE
30
6" LONG
2"

BRASS PIPE

31
32-7/8" LONG
2"

BRASS PIP

32
12" LONG
2"

BRASS PIP

33
6" LONG
2"

BRASS PIP

34
6" LONG
2"

BRASS PIP

35
12" LONG
2"

BRASS PIPE

ITEM
REQ'D
SIZE
DESCRIPTION
36
80
3/4"x3-3/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
37
80
3/4"
HEX NUTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
38
10
12"

RING GASKETS

39
16
5/8"x3-1/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
40
2
4"
RING GASKETS
41
8
5/8"x2-3/4"
MACHINE BOLTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
42
2
2"
RING GASKETS
NOTE: (4) 2” RING GASKETS REQ’D IF FLANGED 2” REGULATOR IS USED
43
24
5/8"
HEX NUTS, STAINLESS STEEL PER ASTM A276/A193, TYPE 304
44
12
12"

RETAINED MECHANICAL JOINTS WITH ACCESSORIES

14
12"

RETAINED MECHANICAL JOINTS WITH ACCESSORIES IF OPTIONAL SOLID SLEEVE USED

45
2
#2

VALVEBOXES SET TO GRADE FOR ITEM #7 (NOT SHOWN ON DRAWING FOR CLARITY)

46
1
12"

**OPTIONAL** RETAINED MECHAICAL JOINT SOLID SLEEVE (SHORT PATTERN)

 

Regulator Specifications

The regulator valve shall be a pressure reducing/pressure sustaining surge control valve of the globe type manufactured by Cla-Val Company (Series 94, CWD Reg.) or OVC Control Valves (Model No: 127-25).

The strainers shall be of the type manufactured by Ross Valve (Model No: 10B/10C).

The pressure reducing valve body and strainer body shall be either cast iron or ductile iron having a working pressure of minimum 250 psi.

All components of the pressure reducing valve assembly shall also have a minimum 250 psi working pressure rating.

The flanges of the pressure reducing valve, strainer, valves and connecting pieces shall have a working pressure of 250 psi with dimensions and drilling of all end flanges conforming to the American 125 lb. Cast Iron Flange Standard. Flanges shall be plain face with a smooth finish.

(SEE DRAWING No. 8REG)

8-4-2008

 
 

Return to top of the page

TEE DETAILS (Drawing Numbers & Description)
DETAIL No.

TEE DETAILS

STD-T01

CUT-IN TEE METHOD #1 (DATED 10-1-97)

STD-T02

CUT-IN TEE METHOD #2 (DATED 10-1-97)

STD-T03

CUT-IN TEE METHOD #3 (DATED 10-1-97)

Return to top of the page

VAULT ARRANGEMENT DETAILS (Drawing Numbers & Description)
DETAIL No.

VAULT ARRANGEMENTS

STD-V01

VAULT AND VALVE ARRANGEMENT REVISED
(DATED 10-1-97)
(Materials Required for Installation - click here)

STD-V02

TYPICAL METER SETTINGS, 3" METER SETTINGS AND LARGER FOR INSIDE BUILDINGS. (DATED 10-1-97)
(Materials Required for Installation - click here)

STD-V03

SINGLE FEED/COMBINATION VAULT DOMESTIC - FIRELINE CONNECTIONS 3" DOMESTIC - 4" - 10" FIRELINE- (DATED 2-25-2009)
(Materials Required for Installation - click here)

STD-V04

SINGLE FEED/SEPARATE VAULTS DOMESTIC - FIRELINE CONNECTIONS 4 " - 12" DOMESTIC - 4" -12" FIRELINE - (DATED 2-25-2009)
(Materials Required for Installation - click here)

STD-V05

SINGLE FEED/SINGLE VAULT FOR FIRELINE CONNECTION/DOMESTIC CONNECTION WITH REMOTE METER/1-1/2" - 2" DOMESTIC/ 4" - 12" FIRELINE
(DATED 11-16-2009)

STD-V06

SINGLE FEED/COMBINATION VAULT DOMESTIC - FIRELINE/DOMESTIC CONNECTION 1-1/2" - 2" DOMESTIC/4" - 8" FIRELINE (DATED 11-16-2009)
(Materials Required for Installation - click here)

DETAIL No.

MATERIALS REQUIRED FOR INSTALLATION

V&VA-01

1-1/2" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-02

2" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-03

3" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-04

4" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-06

6" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-08

8" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

V&VA-12

12" CONNECTION FOR DOMESTIC SUPPLY OR FIRE PROTECTION CONNECTION

Return to top of the page
Copyright City of Cleveland, Division of Water. All rights reserved.

Questions? Call customer service at 216.664.3130 |
Privacy & Security
Copyright City of Cleveland, Division of Water. All rights reserved.
Proud Member of the City of Cleveland-Department of Public Utilities